Abstract

A new procedure to extract intramuscular fat (IMF) was developed to minimize sample amount, solvent use and time of analysis. Lyophilised samples (200mg) were accurately weighed in a safe-lock micro test tube, homogenized in 1.5mL dichloromethane-methanol (8:2) and mixed in a mixer mill (MM400, Retsch technology). The final biphasic system was separated by centrifugation (8min, 10,000rpm). The extraction was repeated three times. Solvent was evaporated under nitrogen stream and lipid content was gravimetrically determined. Results from 64 determinations were compared to those obtained with other referred method and showed a linear response over the whole range of IMF content (1.6–6.9g/100g sample). Moreover, the analysis with different methodology of six replica from the same sample showed lowest variability (standard deviation intra-method) for the new methodology proposed over a wide range of IMF content. A cost and time efficient lipid extraction procedure was developed without loss of precision and accuracy and with a fatty acid profile comparable to other protocols.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.