Abstract

In this work, a label-free and sensitive fluorimetric method has been developed for the detections of biothiols including cysteine (Cys), homocysteine (Hcy), and glutathione (GSH), based on the specific biothiol-induced inhibition of the oxidase-like activity of silver ions (Ag+). It is well established that o-phenylenediamine (OPD) can be oxidized by Ag+ ions to generate fluorescent 2,3-diaminophenazine (OPDox). The introduction of biothiols would inhibit the oxidation of OPD by Ag+ due to the strong coordination between biothiols and Ag+. The changes of fluorescence intensities obtained in the Ag+-OPD system exhibited good linear correlations in the ranges of 0.50–30.0μM for Cys, 1.0–45.0μM for Hcy and 0.50–40.0μM for GSH. The detection limits (S/N=3) of Cys, Hcy and GSH were 110nM, 200nM and 150nM, respectively. Subsequently, the developed fluorimetric method was successfully applied for the detection of biothiols in human serum.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.