Abstract
Underground coal fires (UCFs) cause remarkable loss of energy resources and significant environmental pollution. Understanding the fundamental characteristics of low-temperature oxidation of coal is related to the prevention and detection of UCFs. A lab-scale experimental setup is designed and built to study the coal spontaneous combustion under the natural convection of air into the coal layer. Alumina porous ceramic blocks with through-cuts are employed to simulate the overburden above the coal seam. Temporal variation of coal temperature, exhaust gases temperature and volumetric fractions of CO and CO2 are measured and analyzed. In addition, the thermal anomaly on the overburden surface is monitored, and its correlation with the underneath coal temperature is identified. It is found that air supply is the primary limiting factor that dictates the intensity of coal-oxygen reactions, and the ratio of CO2/CO in the exhaust gases exhibits a strong dependence on the regime of coal-oxygen reactions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.