Abstract

The objective of this study is to examine the performance of a hydrogen compressor by using recently developed porous metal hydride compact technology exhibiting high thermal conductance. The inlet temperatures of the cooling medium for hydrogen storage (20 and 30 ∘ C ), the heating medium for compression (60, 70, 80, and 90 ∘ C ), and the kind of metal hydride ( LaNi 5 and LaNi 4.75 Al 0.25 ) were considered as key parameters. For each condition, transient temperature distributions and compressed pressures were monitored. Results showed that the hydrogen compressor fared better at lower storage temperatures. The research showed that LaNi 4.75 Al 0.25 had a faster absorption rate than LaNi 5 . In addition, the compression ratio was found to be primarily dependent on the temperature difference between cooling and heating; the compression work and the efficiency of the LaNi 5 reactor were slightly larger than those of the LaNi 4.75 Al 0.25 reactor. Under the considered conditions, the maximum work (2.44 kJ) and efficiency (5.91%) occurred when LaNi 5 operated at cooling temperature of 20 ∘ C and heating temperature of 90 ∘ C .

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.