Abstract

A trigger probe measurement system and measurement methodology are developed for kinematic self-calibration of micro/meso-scale machine tools (mMTs). The trigger probe detects the contact between a spindle-mounted stylus and a table-mounted planar artifact. The trigger probe system is small enough to be easily mounted on an mMT. The measurement methodology is divided into off-machine and on-machine measurements. The off-machine measurements are only needed for the first calibration. Recalibration requires only the on-machine measurements to be repeated, thereby reducing recalibration time. The measurement system and methodology are implemented with existing kinematic modeling, error parameter estimation, and compensation techniques for the experimental calibration of a three-axis mMT. The measurement system error is evaluated and experimentally measured. Cutting tests are used to validate the performance of the calibration methodology.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.