Abstract

Melanoma patients with BRAF V600E and V600K mutations show complete or partial response to vemurafenib. Detection assays often scan for the common V600E mutation rather than the rare V600K variant, although this mutation can be found in a high proportion of melanoma patients in the South Pacific. Herein, we describe a BRAF high resolution melting (HRM) assay that can differentiate low level of V600E and V600K mutations using formalin fixed, paraffin embedded (FFPE) reference standards for assay validation. The assay is based on the competitive amplification of differentially melting amplicons (CADMA principle) and has a limit of detection of 0.8% mutant allele for V600K and 1.4% mutant allele for V600E. A differentiation between the two mutations based on the melting profile is possible even at low mutation level. Sixty FFPE specimens were scanned and mutations could be scored correctly as confirmed by castPCR. In summary, the developed HRM assay is suitable for detection of V600K and V600E mutations and proved to be reliable and cost effective in a diagnostic environment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.