Acylcarnitines are essential diagnostic markers for complex diseases and fatty acid metabolism disorders, and play an important role in cardiovascular diseases. Herein, a HILIC-MS/MS method was developed and validated for the rapid quantitation of the acylcarnitines C2, C3, C4, C5, C6, C8, C10, C12, C14, C16, C18, C18:1 and C18:2 in human serum. RPLC and HILIC modes were tested, and HILIC was selected since it provided optimum analyte separation. Intra- and interday accuracy ranged from 90.4% to 114% and from 96% to 112%, respectively, while intra- and interday precision ranged from 0.37% to 13.7% and from 1.3% to 9.5%, respectively. A limit of quantitation (LOQ) of 78.1ng/mL was found for C2, 2.4ng/mL for C3, C18:1 and C18:2, and 1.2ng/mL for C4, C5, C6, C8, C10, C12, C14, C16, and C18. Method validation was performed in accordance with bioanalytical method guidelines. Subsequently the method was applied in the analysis of approximately 1040 samples from patients with coronary artery disease.