Abstract
This study focused on detecting streptomycin (STR) residues using a luminescent aptasensor encapsulated with aptamer. Utilizing MOF-74-Co with peroxidase-like activity, luminol was enclosed in its pores. The specific STR aptamer acted as a gatekeeper, ensuring excellent performance. Upon exposure to STR, the aptamers detached, releasing luminol and amplifying the luminescent signal through MOF-74-Co catalytic activity. A linear relationship between fluorescence intensity and STR concentration (50 nM ∼ 5 × 106 nM) was established, with a limit of detection of 0.065 nM. The sensor exhibited high selectivity for STR even in the presence of other aminoglycoside antibiotics. Applied to tea, egg, and honey samples, the sensor showed recovery rates of 91.38–100.2%, meeting safety standards. This MOF-based aptasensor shows promise for detecting harmful residues.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.