Abstract
In this paper, coupled with hybridization chain reaction and portable personal glucose meter, a highly sensitive aptamer-based immunoassay for vascular endothelial growth factor (VEGF) is fabricated. The antibody immobilized on the microplate captured the target protein, which would be sandwiched by the formation of aptamer/VEGF/antibody complex in the presence of aptamer. And then, an 18-nt elongated strand at the 3′ end of aptamer, with the assist of invertase-functionalized auxiliary probe, triggered the hybridization chain reaction to generate invertase-concatamers. Vast invertase catalyzed sucrose to glucose, which is monitored through personal glucose meter. Finally, this portable sensing system can achieve the detection of limit of 1.2pg/mL with good stability and selectivity. Meanwhile, VEGF in the serum would also be assayed with satisfied result.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.