Abstract

Structural studies on integral membrane proteins are routinely performed on protein–detergent complexes (PDCs) consisting of purified protein solubilized in a particular detergent. Of all the membrane protein crystal structures solved to date, a subset of only four detergents has been used in more than half of these structures. Unfortunately, many membrane proteins are not well behaved in these four detergents and/or fail to yield well-diffracting crystals. Identification of detergents that maintain the solubility and stability of a membrane protein is a critical step and can be a lengthy and “protein-expensive” process. We have developed an assay that characterizes the stability and size of membrane proteins exchanged into a panel of 94 commercially available and chemically diverse detergents. This differential filtration assay (DFA), using a set of filtered microplates, requires sub-milligram quantities of purified protein and small quantities of detergents and other reagents and is performed in its entirety in several hours.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call