Abstract
The piezoresistive effect in a van der Pauw (VDP) stress sensor subjected to biaxial stress was considered. The VDP resistance equations were combined with the silicon piezoresistivity equations to yield relations for the change in resistance of a VDP sensor in terms of the applied state of stress. Then the sensitivity of the VDP sensor to biaxial stress was determined analytically and simulated numerically. The biaxial stress states considered were those for a circular diaphragm under pressure. The VDP sensitivities to biaxial stress were compared to the sensitivity for the conventional piezoresistive stress sensor. It is observed that the theoretical (based on analytical and numerical results) pressure sensitivity of the new VDP sensor is about three times greater than the conventional counterpart.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.