Abstract

We report on the construction and test results of a 8 × 8 module electromagnetic BGO calorimeter with both longitudinally non-segmented modules and modules with longitudinal segmentation for improved electron/hadron discrimination and two shower separation. The data have been taken mainly at the CERN PS accelerator at electron and pion momenta ranging from 0.5–6 GeV/ c. The crystals are read out via large area silicon PIN photodiodes coupled to specially developed low-noise preamplifiers and pulse-processor modules with automatic gain range selection. We discuss the energy and position resolution as well as the performance for particle identification and two shower separation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call