Abstract

A novel weak capacitance measurement system is proposed to measure the gas-solid two-phase flows. The system is mainly consist of capacitance sensor, Micro- programmed Control Unit (MCU), Direct Digital Synthesizer (DDS), operational amplifier, analogue multiplier and low-pass filter. Since the stray capacitance is much larger than the variation of measured capacitance, the stray capacitance should be eliminate by the measurement system. The experimental results show that the system meets the application requirement, and has good linearity, high measurement accuracy and stray-immune. The result of the percentage error is about 0.6% and the non-linear error is less than 1.5%. The sampling rate which is related to the frequency of the signal generator and the MCU clock can reach 500 kps.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.