Abstract

In this paper, a harmonic distortion measurement algorithm and its system design based on time-domain matrix operations are proposed, which can quickly calculate the harmonic amplitudes, phases and total harmonic distortion of a signal. To realize the calculation of harmonic signal parameters in the time domain, we proposed a method to convert the nonlinear function representing the signal into a linear function, constructed a matrix equation, and solved the equation by the row transformation method, which significantly reduced the complexity of the algorithm. Finally, based on the proposed algorithm, a system design was implemented by the digital signal processing theory, and the measurements showed that the system achieves an amplitude error of nearly 1% and a THD error of less than 0.3% when measuring the generated 10 kHz fundamental with 5-order harmonics. The system can be used to measure and calculate the amplitudes and THD of harmonic distortion signals with high precision.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.