Abstract

A direct current homopolar machine with liquid metal contacts can achieve high power density and efficiency. The analysis of a simple model of such a machine shows that a power density of several horsepower per pound at 90 percent efficiency is possible. The results of a design study of an experimental 280-pound 250- horsepower homopolar automotive transmission showed a 90 percent efficiency over a useful operating range. Problems arising during testing limited the efficiency to 75 percent.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.