Abstract
A wavelength and pulse repetition rate (PRR) tunable eye-safe picosecond (ps) optical parametric oscillator (OPO) with high energy is developed using a novel method that operates the OPO in a ps regenerative amplifier (RA). With this method, the PRR can be conveniently tuned and a compact kHz ps OPO can be achieved with a pulse energy of 1–3 orders of magnitude higher than previous works. Based on an angle phase matching type II (θ = 41.4°, φ = 0°) KTA crystal, signal wavelength tunability from 1501 nm to 1565 nm is realized at the PRRs of 5 kHz and 10 kHz, respectively. The highest pulse energy of 21.6 µJ with a pulse width of about 6 ps is obtained at the PRR of 5 kHz and a wavelength of 1532 nm.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.