Abstract

This paper describes a high-accuracy airflow volumetric flowmeter using piezoelectric micromachined ultrasound transducers (pMUTs) arrays based on the transit-time. Two pieces of 10by10 multipled aluminum nitride (AlN) pMUTs arrays at resonant frequency of 980 kHz are employed to transmit and receive ultrasonic signals alternately. The dimension of the fabricated 10by10 array is about $3.5\times 3.5 \text{mm}^{2}$ , so the pMUTs-based flowmeter can conveniently measure the flow rate in small pipes. Leveraging on the high signal to noise ratio (SNR, ∼29 dB) of the pMUTs and good resolution (ns) of the evaluation board, the flowmeter has high accuracy. The relative errors of the correctional volumetric flow are within 3% for the reference flow rate in the range from 0–9 L/min in a pipe with a diameter of 10 mm.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.