Abstract

In a commercialized 300 kW molten carbonate fuel cell (MCFC) power plant, a univariate alarm system that has only upper and lower limits is usually employed to identify abnormal conditions in the system. Even though univariate alarms have already been adopted for system monitoring, this simple monitoring system is limited for using in an extended monitoring system for fault diagnosis. Therefore, based on principal component analysis (PCA), a recursive variable grouping method for a multivariate monitoring system in a commercialized MCFC power plant is presented in this paper. In terms of development, since a principal component analysis model that contains all system variables cannot isolate a system fault, heuristic recursive variable selection method using factor analysis is presented here. To verify the performance of the fault detection, real plant operations data are used. Furthermore, comparison between type 1 and type 2 errors for four different variable groups demonstrates that the developed heuristic method works well when system faults occur. These monitoring techniques can reduce the number of false alarms occurring on site at MCFC power plant.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.