Abstract

AbstractA greener alternative method is proposed for measuring acid values (AV) of fats, oils, and grease (FOG) based on visual titration. Compared with Official Method Cd 3d‐63 of the American Oil Chemists' Society (AOCS), this greener alternative method can eliminate the use of toluene, which in turn reduces toxicity and cost. A total of 44 samples of yellow and brown grease with AV ranging from 0.13 to 170.37 (mg KOH) g−1 were titrated using both methods. The alternative titration method can provide accurate and reliable results to determine the AV of FOG by various statistical analyses including repeatability, linear regression, f‐test, t‐test, and method accuracy calibration with AOCS Cd 3d‐63. This low‐cost method can be recommended for routine titration in research and development, and in biodiesel plants for most FOG samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.