Abstract

This paper presents a new direct electron transfer based-miniaturized glucose/oxygen enzymatic fuel cell (EFC) whose operating ability has been tested in real saliva samples. The bioanode and biocathode are a graphene working electrode and a graphite counter electrode localized on the same screen printed electrode (SPE) modified with poly(vinyl alcohol) N-methyl-4(4′-formylstyryl)pyridinium methosulfate acetal (PVA-SbQ)/cellobiose dehydrogenase from Corynascus Thermophilus (CtCDH) C291Y/AuNPs and with Trametes Hirsuta laccase (ThLac)/AuNPs, respectively.In order to optimize the bioanode, several CDH immobilization procedures were adopted, such as drop-casting, use of Nafion membrane or PVA-SbQ photopolymer. The photopolymer showed the best performance in terms of stability and reliability. As biocathode a partially optimized laccase electrode was employed with the variant that the used nanomaterials allowed to reduce the overpotential of O2/H2O redox reaction catalyzed by Trametes Hirsuta Laccase (ThLac), drop-casted onto the gold nanoparticles (AuNPs) modified SPE.The performances of bioanode and biocathode were tested separately, initially immobilizing the two enzymes onto separated graphene SPEs. An efficient direct electron transfer was achieved for both elements, obtaining an apparent heterogeneous electron transfer rate constant (ks) of 0.99±0.05s−1 for CtCDH C291Y and 5.60±0.05s−1 for ThLac. Both electrodes were then assembled in a two compartment EFC obtaining a maximal power output of 5.16±0.15μWcm−2 at a cell voltage of 0.58V and an open circuit voltage (OCV) of 0.74V. Successively, the bioanode and biocathode were assembled in a non-compartmentalized EFC and a remarkable 50% decrease of the maximum power output at the value of 2.15±0.12μWcm−2 at cell voltage of 0.48V and an OCV of 0.62V at pH 6.5 was registered. In order to reduce the cell dimensions in view of its possible integration in biomedical devices, the bioanode and biocaythode were realized by immobilization of both enzymes onto the same SPE. The so miniaturized EFC delivered a maximal power output of 1.57±0.07μWcm2 and 1.10±0.12μWcm−2 with an OCV of 0.58V and 0.41V in a 100μM glucose solution and in human saliva, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.