Abstract

A glass-reinforced hydroxyapatite (HA) composite (Bonelike®) was developed for bone grafting. This biomaterial is composed of a modified HA matrix with α- and β-tricalcium phosphate secondary phases, resulting in higher solubility than single HA type of materials. Several invitro and invivo studies demonstrated that Bonelike® has a highly bioactive behavior, which was also confirmed by employing granular forms of this biomaterial in orthopedics and dental applications. However, a fast consolidation vehicle was needed to promote the fixation of Bonelike® granules if applied in larger defects or in unstable sites. Surgical-grade calcium sulfate (CS), which is widely recognized as a well-tolerated and inexpensive bone graft material, was the chosen vehicle to improve the handling characteristics of Bonelike® as it can be used in the form of a powder that is mixed with a liquid to form a paste that sets in situ. After application in non-critical monocortical defects in sheep, histological, and scanning electron microscopy evaluations demonstrated that Bonelike® associated to CS functioned as a very satisfactory scaffold for bone regeneration as it achieved synchronization of the ingrowing bone with biomaterial resorption and subsequent preservation of the bone graft initial volume. Therefore, our results indicate that CS is an effective vehicle for Bonelike® granules as it facilitates their application and does not interfere with their proven highly osteoconductive properties. In the opposite way, the incorporation of Bonelike® improves the bone regeneration capabilities of CS.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call