Abstract

A new recapture debugging model is suggested to estimate the number of faults in a system, /spl nu/, and the failure intensity of each fault, /spl phi/. The Gibbs sampler and the Metropolis algorithm are used in this inference procedure. A numerical illustration suggests a notable improvement on the estimation of /spl nu/ and /spl phi/ compared with that of a removal debugging model.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call