Abstract

The ANSI/HPS-N13.1-1999 standard is based on the concept of obtaining a single point representative sample from a location where the velocity and contaminant profiles are relatively uniform. It is difficult to predict the level of mixing in an arbitrary stack or duct without experimental data to meet the ANSI/HPS N13.1-1999 requirements. The goal of this study was to develop experimental data for a range of conditions in "S" (S-shaped configuration) duct systems with different mixing elements and "S" systems having one or two mixing elements. Results were presented in terms of the coefficients of variation (COVs) for velocity, tracer gas, and 10-mum aerodynamic diameter (AD) aerosol particle profiles at different downstream locations for each mixing element. Five mixing elements were tested, including a 90 degrees elbow, a commercial static mixer, a Small-Horizontal Generic-Tee-Plenum (SH-GTP), a Small-Vertical Generic-Tee-Plenum (SV-GTP), and a Large-Horizontal Generic-Tee-Plenum (LH-GTP) system. The COVs for velocity, gas concentration, and aerosol particles for the three GTP systems were all determined to be less than 8%. Tests with two different sizes of GTPs were conducted, and the results showed the performance of the GTPs was relatively unaffected by either size or velocity as reflected by the Reynolds number. The pressure coefficients were 0.59, 0.57, and 0.65, respectively, for the SH-GTP, SV-GTP, and LH-GTP. The pressure drop for the GTPs was approximately twice that of the round elbow, but a factor of 5 less than a Type IV Air Blender. The GTP was developed to provide a sampling location less than 4-duct diameters downstream of a mixing element with low pressure drop condition. The object of the developmental effort was to provide a system that could be employed in new stack; however, the concept of GTPs could also be retrofitted onto existing system applications as well. Results from these tests show that the system performance is well within the ANSI/HPS N13.1-1999 mixing criteria--the COVs for velocity, tracer gas, and 10-microm AD aerosol particles are less than the 20% criteria levels.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.