Abstract
Self-Powered Neutron Detectors (SPNDs) have long been widely used as reactor in-core neutron detectors. However, delayed type SPNDs, a typical type SPND with delayed current component, can not be directly used for real-time neutron flux monitoring. To solve this problem, several researchers have established compensation methods to reconstruct neutron flux. For the various SPNDs with delayed currents, the existing compensation methods are usually case-dependent. Therefore, a general compensation method for delayed type SPNDs with high portability is proposed in this paper. Based on linear equations in the s domain, this method is applicable for all the delayed SPNDs, giving the general compensation solution with definite iterations. Moreover, this compensation method is tested by two typical delayed SPNDs, indicating its high portability and applicability.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.