Abstract

This paper presents a novel system for detecting concentration of the CH4 and CO gases, which exist widely in the coal industry. The system applies micro blazed grating to split the collimated light and may get the infrared absorption light with certain wavelength and bandwidth for the gases detection. The schematic diagram, calculation, signal processing, and setup were described in details. Experimental results indicate that the detection system has the ability to detect methane and carbon monoxide with maximum error of 0.169% and 58.3ppm, stability of 0.76% and 0.22%, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.