Abstract
Clock synchronization is one of the popular research topics in Distributed Measurement and Control Systems (DMCSs). In most industrial fields, such as Smart Grid and Flight Test, the highest requirement for synchronization accuracy is 1 μs. IEEE 1588 Precision Time Protocol-2008 (PTPv2) can theoretically achieve sub-microsecond accuracy, but it relies on the assumption that the forward and backward delays of PTP packets are symmetrical. In practice, PTP packets will experience random queue delays in switches, making the above assumption challenging to satisfy and causing poor synchronization accuracy. Although using switches supporting the Transparent Clock (TC) can improve synchronization accuracy, these dedicated switches are generally expensive. This paper designs a PTP clock servo for compensating Queue-Induced Delay Asymmetry (QIDA), which can be implemented based on ordinary switches. Its main algorithm comprises a minimum window filter with drift compensation and a fuzzy proportional-integral (PI) controller. We construct a low-cost hardware platform (the cost of each node is within USD 10) to test the performance of the clock servo. In a 100 Mbps network with background (BG) traffic of less than 70 Mbps, the maximum absolute time error (max |TE|) does not exceed 0.35 μs, and the convergence time is about half a minute. The accuracy is improved hundreds of times compared with other existing clock servos.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.