Abstract
We developed a custom data reduction algorithm using a random forest and deployed it within an online cloud-based platform, which streams data and communicates interactively with caregivers via a web interface to display algorithm results. We developed real-time, machine learning-based alerting and monitoring system for epilepsy and seizures on continuous electroencephalogram recordings from 77 patients undergoing routine scalp ICU electroencephalogram monitoring and tested it on an additional 20 patients. We achieved a mean seizure sensitivity of 84% in cross-validation and 85% in testing, as well as a mean specificity of 83% in cross-validation and 86% in testing, corresponding to a high level of data reduction. This study validates a platform for machine learning-assisted continuous electroencephalogram analysis and represents a meaningful step toward improving utility and decreasing cost of continuous electroencephalogram monitoring. We also make our high-quality annotated dataset of 97 ICU continuous electroencephalogram recordings public for others to validate and improve upon our methods.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.