A full aperture backscattering light diagnostic system (FABLDS) implemented on the Shen Guang-III Prototype Laser Facility is described in the paper. FABLDS measures both stimulated brillouin scattering (SBS) and stimulated Raman scattering (SRS) with a series of optical detectors. Energy sensors record the integrated energy, and streak cameras coupled with spectrometers measure the temporal spectrum of the backscattering light. This paper provides an overview of the FABLDS and detailed descriptions of the optical path. Special components, including off-axis parabolic mirror, spatial filter and optical light filters, are incorporated along the beam path for purifying the scattering light. Several hohlraum targets were employed, including C5H12 gas-filled targets and empty targets in the experiments. Results presented in the paper indicate that the fraction of backscatter light has been obviously shrinked when the laser is smoothed by continuous phase plates (CPP).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.