Abstract

Based on the internal model principle, repetitive controller (RC) is capable of reducing periodic torque ripple by generating a compensating action that consequently needs to be synchronized with the original ripple. However, the synchronization is difficult to achieve using the conventional RC when the sampling frequency is not integer multiple of the speed (known as fractional delay issue) or when the speed varies widely. To solve this problem, this paper presents a fractional delay variable frequency torque ripple reduction method for permanent magnet synchronous machine drives using the combination of angle-based RC and deadbeat current control. Four aspects of innovations are included in the proposed control to improve the synchronization. The experimental results show that the proposed control can effectively reduce torque ripple, even during speed and load transient.