Abstract

An algorithm, based on the χ 2 test, employed for particle identification by RICH detectors, is described. This algorithm is independent and complementary to the traditional algorithm based on the comparison between the average of the measured Cherenkov angles and the expected Cherenkov angles of the photons generated in the RICH by the particle to be identified. On the other hand it is much simpler and faster than a full likelihood analysis of the full event pattern. The particle rejection ratios achievable with the combined use of this algorithm and the algorithm based on the comparison between the average and the expected Cherenkov angles are very high. The algorithm also allows one to identify noise easily. The application of the algorithm is shown for the Hall A RICH detector in the E94-107 experiment at JLab. In this experiment an enormous background made up of pions and protons is 30 000 times bigger than the signal and had to be identified and rejected in order to extract the kaons from the electroproduction of hypernuclei.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.