Abstract

This paper provides details of a force platform assembly suitable for measuring the magnitude, position and direction of ground reaction forces for manual handling tasks involving several footsteps in any horizontal direction. An approach to increase the natural frequency with the use of a vibration absorber is used; this frequency was found to be 41±2 Hz. The results show a maximum error of 22 N (2% of the full scale output) when a person performs repetitive movements from a squat position to a full extension and back to the squat position. Static tests show the maximal errors to be, vertically, 1.5% of the full scale output (1818±33 N), and horizontally, 4.9% of the full scale output (1177±6 N).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.