We introduce a folded configuration of a previously described Sagnac interferometer-based sensor array. It is shown that the folded configuration lessens the detrimental effects of distributed phase modulations in the delay coil while also reducing the required delay coil length by a factor of 2. A prototype two-sensor array was constructed and measured to perform according to theory, exhibiting a phase sensitivity of roughly 3μrad/Hz in a single-port detection configuration and 0.8μrad/Hz in a balanced detection configuration. The desensitization of the delay coil was measured to agree with theory.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.