Abstract

This article aims to describe a simple and reliable technique that helps in positioning the cannulated percutaneous screws during fixation of depression-type tibial plateau fractures. After fracture reduction under arthroscopic control, an outside-in anterior cruciate ligament femoral guide is introduced through the tibial cortical metaphyseal window and positioned under endoscopic control just underneath the elevated fragment. When proper height is achieved, a guide pin is drilled from lateral to medial through the sleeve, 1 to 2 cm distal to the articular surface of the depressed fragment. The cannulated screw can then be introduced under endoscopic control, without fluoroscopic assistance, just under the previously elevated joint surface. This technique ensures optimal placement of the cannulated screw in the middle of the bony tunnel to obtain optimal subchondral bone support during fixation of the depressed tibial plateau fracture.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.