Abstract

A fluorometric determination of urinary 17-hydroxycorticosteroids using a reaction of benzamidine with compounds carrying the dihydroxyacetone side chain is described. The fluorescent compounds have excitation and emission maxima at 370 and 480 nm, respectively. The method includes enzymatic hydrolysis with β-glucuronidase (EC 3.2.1.31, from Escherichia coli) and extraction with methylene chloride and generation of fluorescence in alkaline solution (pH 13.4). The specificity of the reaction was examined and the results were compared with those of an accepted method based on the Porter-Silber reaction ( C. C. Porter and R. H. Silber, 1950, J. Biol. Chem. 185, 201–207 ). The coefficient of correlation was 0.945 with regression line of y = 0.91 x + 0.7 mg/day ( y, present method; x, Porter-Silber reaction method). Sensitivity of the reaction was 0.5 μg/ml of standard or sample, mean recovery of cortisol added to five urine samples (5-μg addition) was 95%, and the coefficient of variation of the method (five repeated assays of sample with a value of 5.2 mg/liter) was 6.2%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.