Abstract

This paper proposes a flexible eddy current TMR (FEC-TMR) sensor to monitor the internal crack of metal joint structures. First, the finite element model of the FEC-TMR sensor is established to analyze the influence of the sensor’s crack identification sensitivity with internal crack propagation at different depths and determine the optimal location and exciting frequency of the sensor. Then, the optimal longitudinal spacing and exciting frequency of the sensor are tested by experiment. The experimental results are consistent with the simulation results, which verify the correctness of the simulation model. Finally, the experiment is carried out for internal cracks of different depths to verify that the sensor can monitor internal cracks, and the crack identification sensitivity gradually decreases with the increase in the depth of the crack from the surface.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.