Abstract
In this work, a multi-walled carbon nanotube-modified flexible poly(styrene-butadiene) fiber membrane material was prepared for the sensitive and selective electrochemical detection of dopamine (DA) in human serum and DA injection. The flexible fiber membrane prepared by electrospinning technology is expected to realize its application in wearable devices. The obtained conductive film-based electrochemical sensor can effectively minimize interference caused by ascorbic acid and uric acid. Under the optimized experimental conditions of differential pulse voltammetry, DA gives a linear response in the range of 1–650 μM (R2 = 0.996). The detection limit of DA (signal-to noise ratio = 3) was determined to be 0.062 μM.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.