Abstract

Common-mode voltages generated by PWM inverters in induction motor drives cause shaft voltages, bearing currents and ground leakage currents resulting into early mechanical failure of machine bearings and conducted EMI. A five-level inverter topology with switching state combination selection strategy for the PWM control is proposed for an open-end winding induction motor drive, which completely eliminates the common-mode voltages at inverter poles and machine phase windings, in the complete modulation range of the drive. The proposed induction motor drive structure offers reduced device count, simple power-bus structure and more number of redundant switching state combinations when compared to a conventional five-level NPC inverter fed induction motor drive. The DC-link voltage requirement for the proposed five-level inverter fed drive scheme is half compared to that of conventional five-level inverter fed drive and hence it needs power devices with lower blocking voltage capability, which makes the proposed inverter topology suitable for high power induction motor drive applications

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.