The natural circulation test (NCT) was conducted in the Phénix prototype French 580MWth sodium fast reactor (SFR) in 2009. The main goal of the Phénix NCT is to validate system- and CFD-codes with respect to the establishment of natural circulation in the primary system of a pool type SFR. The present paper describes the calculation of the NCT by coupling the 3D computational fluid dynamics (CFD) code TRIO_U with the best estimate thermal hydraulic system code CATHARE. The coupling methodology and the modeling at the system and at the CFD scales are first presented. A validation of the coupling methodology based on a coupled CATHARE/CATHARE calculation compared to the standard CATHARE predictions is then proposed. In a second step, the results of the TRIO_U/CATHARE calculation are compared both to the available experimental data and to the results of a CATHARE alone computation. These comparisons highlight the effectiveness of coupling CFD- and system-codes for the analysis of plant transients where three-dimensional phenomena play an important role.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.