Abstract

A finite model was established to predict the radiation field around a line lamp treating contaminated air, taking into account the effects of the radius of the lamp and sleeve, as well as other physical parameters. Both irradiance and fluence rate could be calculated, and the model was validated with measured data and by comparison with a conventional extense source volumetric emission (ESVE) model. Diffuse and specular emissions for a line lamp were compared, showing that diffuse emission is more appropriate for a low pressure mercury UV lamp. Refraction by the lamp sleeve can induce a 12% increase in fluence rate near the sleeve, while reflection causes a 7% decrease. When the attenuation coefficient of a gaseous chemical is less than 0.04 m −1 the error due to ignoring its light absorption is less than 1%, within a distance of 0.2 m from the lamp.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.