Abstract

A series of field tests using controlled blasting was conducted at a location in the North Western part of Singapore to assess the behaviour of pile foundations subjected to ground excitation. The field tests involved three piles with different pile head fixity conditions. The piles were instrumented with strain gauges to evaluate the bending moments and axial force along the piles. For the fixed-head piles, the maximum bending moment occurred at the pile head level. For free-head pile exhibited higher bending moments close to the mid-height of the pile and zero bending moment at the pile head due to the absence of restraints at the top. For all cases, the axial force was maximum at the pile head.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.