In practical operation, pump turbines typically operate far from their designed working points, which has a significant impact on the stability of the unit’s operation. In this paper, we conducted a field test to investigate the stability characteristics of prototype pump turbines at different working points. By adjusting the given power of the generator in a stepwise manner to control its working point, we obtained the statistical and spectral characteristics of pressure signals and acceleration signals. In turbine mode, the result shows that, at low, medium, and high power, the variation in pressure fluctuation characteristics is influenced by three different factors, while vibration generally reaches its maximum value at approximately 50 MW. In pump mode, variations in pressure were observed among different measurement points in the low-frequency range, and the characteristics of vibration acceleration were influenced by both the rotor–stator interaction (RSI) and the structural modal frequencies. We emphasized that the high-frequency bands have influences on the unit comparable in magnitude to those of the rotor–stator interaction, which has rarely been mentioned in previous studies. Through detailed testing and analysis of the unit’s actual operation, we can gain a better understanding of its behavior and performance in the turbine and pump modes, and these results hold significant importance for ensuring the stability and reliability of the unit.