Abstract

In order to evaluate stabilisation systems in trochanteric femoral fractures with finite element (FE) analysis, a realistic model is required. For this purpose, a new model of a femur with all the relevant muscles and the hip capsule ligaments is set up. The pelvic and tibial bones are modelled as rigid bodies so as to take all the muscles attached to the femur into account. Fracture zones in the proximal femur are defined. Following the modelling of the geometry, the isotropic material behaviour and the load application, a numerical calculation of the femur is carried out. The static iterated FE simulation shows good agreement with in vivo data for the one-leg-stance phase during walking and Pauwels' one-leg stance regarding the displacement of the femoral head (2.9 and 5.2 mm, respectively) and the resulting hip force (253% and 294% bodyweight, respectively). In the modelled fracture zones without osteosynthesis, shear is higher than axial strain. The reduction of shear among others could be a criterion for judging the quality of a stabilisation implant.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.