Abstract

This paper describes a fault-tolerant control system for a high performance induction motor drive.A new fault-tolerant scheme using three microprocessor-based controllers is presented. In the proposed scheme, two of the three processors always compare the results of their computations with each other in order to detect a fault, and when a fault is detected, the third processor is used to locate it. By this, the proposed scheme guarantees high reliability and provides the flexibility for the utilization of redundancies. Through the comparison of the estimated reliability, it is verified that the proposed scheme gives higher reliability than the TMR (Triple Modular Redundancy) to the control system for the induction motor drive.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.