Abstract

A recently developed T2-preparation module for cardiac imaging at high field is insensitive to B0 and B1 inhomogeneity, cardiac motion and flow. Obtained T2 weighted images exhibit bright fat signal that can obscure the signal of myocardium and other muscles. Therefore, a chemical selective saturation (CHESS) is usually applied for fat suppression after the T2-preparation, e.g. in coronary artery MRI. Its quality is often poor and it is unsuited for longer readout durations. In this study, we propose a new fat suppressed T2-preparation module for 3T using binomial composite RF pulses as 90° pulses to more efficiently suppress fat, maintaining robustness towards inhomogeneity, cardiac motion, and flow. Methods An oil and water phantom was scanned on a Siemens MAGNETOM Trio 3T MR scanner (16-channel coil) to compare the proposed fat-suppression method with the existing T2-preparation using CHESS fat-suppression. The proposed T2-preparation method as shown figure 1 with integrated fat-suppression uses refocusing pulses shown in a previous study [1] to be insensitive to cardiac motion, blood flow, B0 and B1 field. The preparation module is composed of 3 parts. First, a composite binomial pulse consisting of 3 rectangular pulses with1:2:1 amplitude ratio for tipping water spins onto the transverse plane using 22.5° - 45° - 22.5° flip angles. Second, four BIREF-1 [2] pulses for refocusing water spins. Third, a composite binomial pulse (22.5° - 45° - -157.5°) to rotate water and fat spins onto the +Z and -Z axis, respectively. Fat suppression was achieved when the inverted fat spins reached the zero crossing of the fat recovery curve while acquiring the center of k-space during segmented scanning. The scan parameters were ECG gated 2D FLASH sequence, TR/TE = 4.04/1.63 ms, T2-prep time = 40 ms, # of segments = 21, water-fat out of phase time = 1.23 ms, flip angle = 20, FOV = 250 x 210, Matrix = 256 x 216, Thickness = 5 mm, simulation RR = 800 ms, trigger pulse =2 , trigger time =5 80 ms. To evaluate the fat suppression capability of the proposed method, signal-to-noise ratio (SNR), water-fat signal ratio and fat heterogeneity were measured. The heterogeneity was defined as standard deviation of normalized fat signal intensity. Results

Highlights

  • A recently developed T2-preparation module for cardiac imaging at high field is insensitive to B0 and B1 inhomogeneity, cardiac motion and flow

  • Obtained T2 weighted images exhibit bright fat signal that can obscure the signal of myocardium and other muscles

  • We propose a new fat suppressed T2-preparation module for 3T using binomial composite RF pulses as 90° pulses to more efficiently suppress fat, maintaining robustness towards inhomogeneity, cardiac motion, and flow

Read more

Summary

Background

A recently developed T2-preparation module for cardiac imaging at high field is insensitive to B0 and B1 inhomogeneity, cardiac motion and flow. Obtained T2 weighted images exhibit bright fat signal that can obscure the signal of myocardium and other muscles. A chemical selective saturation (CHESS) is usually applied for fat suppression after the T2-preparation, e.g. in coronary artery MRI. Its quality is often poor and it is unsuited for longer readout durations. We propose a new fat suppressed T2-preparation module for 3T using binomial composite RF pulses as 90° pulses to more efficiently suppress fat, maintaining robustness towards inhomogeneity, cardiac motion, and flow

Methods
Results
Conclusions