Abstract
Electromagnetic ultrasonic testing technology has advantages in measuring the thickness of pipelines in service. However, the ultrasonic signal is susceptible to corrosions on the internal and external surfaces of the pipeline. Since the electromagnetic ultrasonic signal is nonlinear, and a dynamic model is difficult to establish accurately, in this paper, a new unscented Kalman filter (UKF) method based on a sliding mode observer (SMO) is proposed. The experiments, conducted on five different testing samples, validate that the proposed method can effectively process the signals drowned in noise and accurately measure the wall thickness. Compared with FFT and UKF, the signal-to-noise ratio of the signals processed by SMO–UKF shows a maximum increase of 155% and 171%. Meanwhile, a random assignment method is proposed for the self-regulation of hyper parameters in the process of Kalman filtering. Experimental results show that the automatic adjustment of hyper parameters can be accomplished in finite cycle numbers and greatly shortens the overall filtering time.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.