Abstract

A frequency converter is usually used in high-power laser facilities to triple the frequency of the incident laser. It consists of a KDP crystal and a KD*P crystal in series. The measurement of the detuning angles of the frequency converter is essential for improving the frequency conversion efficiency. In this paper, we propose a measurement method that uses a diverging beam to illuminate the frequency converter and get the detuning angles by analyzing the light intensity distribution of the third harmonic laser. The simulated results show that there is a strict linear relationship between the characteristic parameters and the detuning angles of frequency converter, verifying the feasibility of this method. Compared with existing measurement methods, its optical path is simple, and the single measurement time can be shortened to a few minutes from a few hours.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.