Abstract

The analysis of toxic and essential elements in human matrices is used in clinical diagnostics and for biomonitoring of different populations to study related health outcomes. This work aimed to develop fast and reliable methods for the analysis of a broad range of elements in liquid human matrices, such as whole blood, serum, and urine, with a similar setup for the three matrices and different analysis needs. An easy and fast‐forward dilute‐and‐shoot method for 33 elements (i.e., Ag, Al, As, B, Ba, Be, Bi, Cd, Ce, Co, Cr, Cu, Hg, I, Li, Mn, Mo, Ni, Pb, Pd, Pt, Sb, Se, Sn, Sr, Te, Th, Tl, U, V, W, Zn, and Zr) was developed. 200 µL of either sample material was diluted with an alkaline reagent to a volume of 4 mL in total. Sample dilution and preparation of matrix‐matched calibration standards were performed in 48‐well plates by an automated liquid handler. Diluted samples were analyzed by inductively coupled plasma mass spectrometry on a Perkin Elmer NexIon 300D ICP‐MS instrument equipped with an ESI‐FAST SC2DX autosampler in kinetic energy discrimination mode with helium as cell gas at either 4.8 mL or 5.7 mL and 1600 W RF generator power. The method validation results showed good accuracy for fresh human samples from an external quality assessment scheme with measured concentrations within the assigned concentration ranges. Good precision and reproducibility for most elements were demonstrated with variation coefficients below or far below 8% and 15% for whole blood, 8% and 10% for serum, and 10% and 10% for urine, respectively. The developed reagent and instrumental setup were applicable to all three matrices. This minimizes the risk of human errors when switching between analyses of the different sample matrices and allows a rapid and easy analysis of whole blood, serum, and urine within one day if needed. The method demonstrated robustness over time, withstanding minor changes in the preparation of working solutions and samples, instrumental analysis, and setup. Analysis of human real samples showed the method’s applicability for 33 toxic and essential elements in whole blood, serum, and urine and at concentrations relevant to clinical diagnostics as well as biomonitoring.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.