Abstract

The photonic mixer device (PMD) solid-state array lidar, as a three-dimensional imaging technology, has attracted research attention in recent years because of its low cost, high frame rate, and high reliability. To address the disadvantages of traditional PMD solid-state array lidar calibration methods, including low calibration efficiency and accuracy, and serious human error factors, this paper first proposes a calibration method for an array complementary metal–oxide–semiconductor photodetector using a black-box calibration device and an electrical analog delay method; it then proposes a modular lens distortion correction method based on checkerboard calibration and pixel point adaptive interpolation optimization. Specifically, the ranging error source is analyzed based on the PMD solid-state array lidar imaging mechanism; the black-box calibration device is specifically designed for the calibration requirements of anti-ambient light and an echo reflection route; a dynamic distance simulation system integrating the laser emission unit, laser receiving unit, and delay control unit is designed to calibrate the photodetector echo demodulation; the checkerboard calibration method is used to correct external lens distortion in grayscale mode; and the pixel adaptive interpolation strategy is used to reduce distortion of distance images. Through analysis of the calibration process and results, the proposed method effectively reduces the calibration scene requirements and human factors, meets the needs of different users of the lens, and improves both calibration efficiency and measurement accuracy.

Highlights

  • Three-dimensional (3D) measurement technologies have been widely used in surveying, structural measurements, virtual reality, and unmanned driving over the past few decades [1,2,3,4,5]

  • By analyzing the ranging error of photonic mixer device (PMD) solid-state array lidar, this paper proposes a calibration method for a CMOS photodetector array based on a black-box calibration device and an electrical analog delay method

  • To address the disadvantages of the traditional PMD solid-state array lidar calibration method, which include low calibration efficiency, low calibration accuracy, and serious human factors, this paper proposed a calibration method for a CMOS photodetector array based on a black-box calibration device and an electrical analog delay method

Read more

Summary

Introduction

Three-dimensional (3D) measurement technologies have been widely used in surveying, structural measurements, virtual reality, and unmanned driving over the past few decades [1,2,3,4,5] Among these technologies, and unlike two-dimensional (2D)/3D mechanical scanning lidar [6,7], which requires fast rotation scanning to obtain depth data, solid-state array lidar based on time-of-flight measurements provides the metric distance to the scene from the sensor [8,9,10]; in particular, photonic mixer device (PMD) solid-state array lidar can reduce the reliability problems associated with mechanical rotating equipment and increase the frame rate while reducing the complexity of 3D reconstruction from the data.

Methods
Results
Discussion
Conclusion