Abstract

Monitoring biosignals at the skin interface is necessary to suppress the potential for decubitus ulcers in immobile patients confined to bed. We develop conformally contacted, disposable, and breathable fabric-based electronic devices to detect skin impedance, applied pressure, and temperature, simultaneously. Based on the experimental evaluation of the multifunctional sensors, a combination of robust AgNW electrodes, soft ionogel capacitive pressure sensor, and resistive temperature sensor on fabric provides alarmed the initiation of early-stage decubitus ulcers without signal distortion under the external stimulus. For clinical verification, an animal model is established with a pair of magnets to mimic a human decubitus ulcers model in murine in vivo. The evidence of pressure-induced ischemic injury is confirmed with the naked eye and histological and molecular biomarker analyses. Our multifunctional integrated sensor detects the critical time for early-stage decubitus ulcer, establishing a robust correlation with the biophysical parameters of skin ischemia and integrity, including temperature and impedance.