Abstract

After investigation in many continuous casting shop of steel, a dynamic water distribution model is proposed for flexible control on secondary cooling in continuous casting. In this model, the water cooling intensity is determined by the model casting speed instead of the real casting speed. When the casting speed is steady, the model casting speed is equal to the real casting speed. When the real casting speed is changing, the model casting speed according to calculating algorithm to adjust and approaches to the real one, but there is a time delay between them, so it can avoid the slab surface temperature fluctuated due to casting speed changes. The secondary cooling can be dynamically controlled by monitoring the model casting speed. The compare of the simulation results and the measured results reveals that the temperature field and thickness of slab shell in simulations agree very well with the real production situations.